6 Communication settings and guide of HMI connecting with controller
Trio controller communication settings
Omron protocol:
define Host Link slave node
HLS_NODE=1
define Host Link slave mode code
HLS_MODEL=$FA
Set up Host Link slave for port 2
Trio controller settingSETCOM (baudrate, databits, stopbits, parity, port, 5)
SETCOM960072225
MC controller unit can communicate with plc terminal after setting the configuration.
NoteA is the programming port of controllerB is the communication port.
Modbus Protocol
address=1
Setcom (9600, 8, 1, 0, 1, 4)
Supported Device
TRIO
Device Bit Address Word Address Format Notes
I/O and Internal Auxiliary Relay IR0.0-1023.15 ———— DDDD.DD
Data Memory ———— DM0-30000 DDDDD
Note
Address correspondence: IRn.m-->the m Trio VR (n); DMn->Table (n). Example IR1.02 corresponds
to the 2nd bit of VR1.
Modbus RTU Extend
Device Bit Address Word Address Format Notes
Data register bit 4X_bit 0.0-1023.15 ———— DDDD.DD